Add to Cart
Neware 5V60A Battery Capacity Discharge Test System Lithium Titanate Battery Cycler
1 . Capacity or energy is calculated on time basis with the voltage and current measured , thus the timing accuracy will greatly affect the capacity calculated. To a general constant current or other constant testing regimes , this effect may not that easy to be observed .
2 . Neware battery testing system utilizes LAN as the main framework to transfer data . This provides the most flexibility and reliablity to your system deployment .
3 , The Neware battery tester models listed below here in different categories are the most popular ones chosen by our customers , so if you belong to one of the following category , then it might be easier for you to find out the battery tester that meets your requirement based on your peers choice .
4 , Battery researchers and scientists, battery manufactures , importers and exporters, you can always choose the most appropriate Neware battery testers for battery quality check , battery performance tests, battery material research , and battery mass production lines .
5 . When you look down into Neware battery tester , its unique Middle Machine architecture provides another enhancement layer to the data security issue . Moreover , this MM is an embedded system that allows you run tests even your LAN is down .
| resolution | AD 16bit , DA 16bit | |
| Input Resistance | More than 1MΩ | |
| Input Power | 4253W | |
| Channel Features | Constant Current Source and Constant Voltage Source with Independent pairs of Closed - loop Structure | |
| Channel Control Mode | Independent Control | |
| Time | Current Response Time | 20ms |
| Charge | Charge Mode | CCCharge , CVCharge , CCCVCharge , CPCharge |
| End Conditon | Voltage , Current , Relative Time , Capacity , -deltaV | |
| Discharge | Discharge Mode | CCD , CPD , CRD |
| End Condition | Voltage , Current , Relative Time , Capacity | |
| Pulse | charge | CCC , CPC |
| Discharge | CCD , CPD | |
| Min Pulse Width | 500ms | |
| Automated Switch | Automated swith from charge to discharge for each pulse | |
| End Condition | Voltage, Test Time | |
| Cycle | Loop Measure Range | 65535 times |
| Max Steps Per Loop | 254 | |
| Nested Loop | Nested loop Function , Max Support 3 Layers | |
| Voltage and Current Testing Sample | 4 - wire connecting | |
| Noise | Less than 85dB | |
| Data Output | EXCEL , TXT , Graph | |
| Communication Interface | Ethernet Port | |
| Per Unit Main Channels No. | 8 | |