Add to Cart
Neware 20V6A 18650 Battery Series Charger Capacity Test Machine 8 Channel
Software Feature
1 , Windows - based software interface for easy operation .
2 , Uses standard SQL data-base management .
3 , Real - time monitoring windows and integrated graph / data windows can set various working modes for measuring capacity and cycle life of all types of rechargeable batteries , such as , constant current discharge , constant current charge , constant voltage charge , rest , as well as voltage , current , time , capability , negative voltage slope , and other limit conditions .
4 , The user can define the curve by different types such as voltage - time curve , current - time curve , capacity - voltage curve ,
loop times - charge / discharge capacity curve , loop times - charge / discharge efficiency curve , etc . to make curves be compared both by visually and statistically .
5 , Provide timely instructions , warnings , and intelligent support .
6 , Compliance CE Certified .
HPPC , Capacity , Cycle Life , Formation and Grading , Over - charge , Over - discharge
Market - Proven Testing System
Less than 20ms Response Time to Meet Rapidly Changing Power Requirements .
0.1 percent Full - scale Accuracy for Current and Voltage .
10Hz Data Acquisition Frequency , 100Hz Optional .
500ms Minimum Pulse Width More Than 1 Million Records Can Be Processed .
20ms Response Time
This fast response time will meet rapidly changing power requirements
Flexible Integration of Hardware and Data Management
BTS 4000 functions also as the core part of auto formation and grading system . With its structural data system , testing data can be analysed , summarized , managed and utilized by our extended program or customers own data and logic server .
Channel Control Mode | Independent Control | |
Voltage | Per Channel Voltage Range | 100mV - 20V |
Discharge Min Voltage | 2.5V | |
Accuracy | 0.1percent of FS | |
Stability | 0.1percent of FS | |
Current | Per Channel Current Range | 30mA - 6A |
Accuracy | 0.1percent of FS | |
Stability | 0.1percent of FS | |
Power | Per Channel Output Power | 120W |
Stability | 0.1 percent of FS | |
Data Recording | Record Condition | Time delta T , 100mS |
Pulse | Charge | CCC |
Discharge | CCD | |
Min Pulse Width | 500ms | |
Automated Switch | Automated swith from charge to discharge for each pulse | |
End Condition | Voltage , Test Time | |
Cycle | Loop Measure Range | 65535 times |
Max Steps Per Loop | 254 | |
Nested Loop | Nested loop Function , Max Support 3 Layers | |
Protection | Software Protection | Power - down Data Protection |
Off - line Testing Function | ||
Setting Protection Condition , Setting Parameter - Low Voltage limit / Upper Voltage limit / Low Current limit / Upper Current limit / Delay Time | ||
Hardware Protection | Additional Anti - reverse Protection Model |