Add to Cart
Neware 5V6A 8 Channel Battery Test Equipment Polymer 3C Battery Cycler
1 . For customers who came across Neware the first time , 5V6A is also strongly suggested as their tryout demo machine .
2 . Neware works on the very popular coin cell , cylindrical cell and prismatic cells , etc . It can be used for battery formation and grading , cycle - life test , performance and so on .
3 . Higher range 100mA - 3A - 6A , makes it the best choice for cycle - life test and C - Rate test on 3C battery cells . Lower range 0.5mA - 100mA - 1A , makes 5V6A great for small pouch , coin cell and small battery test .
4 . Nowadays battery capacity density becomes higher and higher , thats the trend of this whole energy industry , people need smaller dimension battery to contain more energy .
5 . New technology and upgraded producing process make this idea come into reality .
6 . Of course , high C - Rate charge - Quick charge is another reason for higher current testers become more popular than before .
7 . For a 3000mAh cell battery , people want to charge it at 6000mA - 2C or even 9000mA - 3C current . And in some labs , researchers are trying 10C or even higher C - Rate charge or discharge .
8 . The test of polymer batteries and super capacitors need Neware special accessories . Cylindrical batteries need to be clamped between the upper and down clamps of the equipment . By moving the position of the upper accessory accurately according to the scales on both sides , you can test different capacities of Cylinders Batteries .
Input Resistance | More than 1MΩ | |
Input Power | 425W | |
Current | Per Channel Current Range | Range1 , 5mA - 1A Range2 , 1A - 3A Range3 , 3A - 6A |
Accuracy | 0.05 percent of FS | |
Stability | 0.05 percent of FS | |
Power | Per Channel Output Power | 30W |
Stop current | Range 1 , 2mA Range 2 , 12mA Range 3 , 24mA | |
Stability | 0.1percent of FS | |
Data Recording | Record Condition | Min Time - 100mS |
Min Voltage - 10mV | ||
Record Frequency | 10Hz | |
Pulse | charge | CCC , CPC |
Discharge | CCD , CPD | |
Min Pulse Width | 500ms | |
Automated Switch | Automated swith from charge to discharge for each pulse | |
Cycle | Loop Measure Range | 65535 times |
Max Steps Per Loop | 254 | |
Nested Loop | Nested loop Function , Max Support 3 Layers | |
Protection | Software Protection | Power - down Data Protection |
Off - line Testing Function | ||
Setting Protection Condition,Setting Parameter - Low Voltage limit , Upper Voltage limit , Low Current limit , Upper Current limit , Delay Time |