Neware 500V100A Regenerative Battery Pack Testing equipment and Charge Discharge Tester
The CE - 6000 series battery testing system supports channels to expand .
Modularization - Each module is 4 channels 120V50A . Expandable for 8 channels / 12 channels, etc , in one cabinet .
Parallelled , Up to 4 channels to be parallelled connection , can reach 200A in one module .
Regeneration - The regenerative function is included to greatly reduce power consumption during the discharge test .
Communication - Able to log parameters from BMS , Chamber, I / O signals as a condition for cut - off or protection during testing . Support CANbus , RS485 protocol , SMbus , I2C.
Simulation - Because of high dynamic response speed , it supports the profile dynamic simulation , such as DCIR , HPPC , NEDC , FUDC , and other tests .
| Charge | Charge modes | Constant current , Constant voltage , Constant current and voltage , Constant power |
| Cut - off condition | Main channel - Voltage , Current , delta Time , Capacity , - delta V | |
| Discharge | Discharge modes | Constant current , Constant voltage , Constant power , Constant resistance |
| Cut - off condition | Main channel - Voltage , Current , delta Time , Capacity |
| Pulse | Charge | Constant current , Constant power |
| Discharge | Constant current , Constant power | |
| Min pulse width | 100ms | |
| Pulse counts | Each pulse step supports 32 different pulses | |
| Chg and Dschg switch | Supported | |
| Cut - off condition | Voltage , Time | |
| Simulated Condition | Charge modes | Constant current , Constant power |
| Discharge modes | Constant current , Constant power | |
| Cut - off condition | Time , Line Number | |
| Continuous switching Chg and Dischg | One simulation step can realize a continuous switching from charging to discharging | |
| Limit step number | 1 million | |
| Cycle | Max cycles | 65535 |
| Max steps | 254 | |
| Cycle nest | Nested loop Function , Max Support 3 Layers | |
| Protection | Software protection | Power - off data protection |
| Off - line operation mode | ||
| User - defined protection conditions , such as upper and lower limited current / voltage , delay time , temperature , etc . | ||
| Charge and discharge efficifency | more than 90 percent | |
| Protection | Anti - surge , anti - islanding , over - under - frequency , over - under - voltage , phase - loss protection , etc. | |
| Protection grade | IP20 | |
| Channel parallel | supported , Parallel channels do not support pulse and simulation testing | |
| Energy feedback | The discharge energy can be fed back to the power grid | |
| Channels feature | Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure |
| Channels control mode | Independent control |
| Noise | ≤65dB |
| Database | MySQL |
| Communication | TCP/IP |
| Operating system | Windows 7/8/10 64bit |
| Data export | EXCEL, TXT |
| Min. disk drive | 500GB |
| Communication port | Ethernet port |