Add to Cart
Neware Regenerative Battery Pack Cycle Tester 200V200A Canbus DBC Test System
CE - 6000 series regenerative battery module pack tester designed for secondary battery charge / discharge test , specialized in testing high power module / pack battery .
1 . It has a high dynamic response speed , high accuracy .
2 . Also , the regenerative function is included to greatly reduce power consumption during the discharge test .
The CE - 6000 series battery testing system supports channels to expand . Multi - channel can be chosen. Each module is 120V50A , and you can add the module according to your real test requirement . Each module has built - in parallel channels . The parallel function aims to increase the max current in real tests , saving the cost to expand the large range . The parallel function also is safety and reliability . Furthermore , withing using powerful BTS80 software which independent develop by Neware , you can test the driving simulation test , HPPC test , DCIR test , capacity test , and other tests required high sample data rate, high accuracy , and high response speed .
CE - 6000 series battery testing system , Power battery simulation test, rate test . Cycle life test . Power, capacity and energy detection .
Virtual configuration of power battery pack , charge and discharge curve fitting, battery consistency detection and evaluation .
High rate charge and discharge ability detection .
Power battery , energy storage battery series module detection , monomer voltage, monomer temperature monitoring - high voltage equipment .
Charge | Charge modes | Constant current , Constant voltage , Constant current and voltage , Constant power |
Cut - off condition | Main channel - Voltage , Current , delta Time , Capacity , - delta V | |
Discharge | Discharge modes | Constant current , Constant voltage , Constant power , Constant resistance |
Cut - off condition | Main channel - Voltage , Current , delta Time , Capacity |
Simulated Condition | Charge modes | Constant current , Constant power |
Discharge modes | Constant current , Constant power | |
Cut - off condition | Time , Line Number | |
Continuous switching Chg and Dischg | One simulation step can realize a continuous switching from charging to discharging | |
Limit step number | 1 million | |
Protection | Software protection | Power - off data protection |
Off - line operation mode | ||
User - defined protection conditions , such as upper and lower limited current / voltage , delay time , temperature , etc . |
Channels feature | Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure |
Channels control mode | Independent control |
Noise | ≤65dB |
Database | MySQL |
Communication | TCP/IP |
Operating system | Windows 7/8/10 64bit |